Dual laminate vessels, stamped to ASME RTP-1 Appendix M-12
Thermoplastic lined FRP equipment with mechanically bonded or chemically bonded linings (lining classification A).

Certification
RL Industries is certified by ASME to stamp dual laminate FRP vessels per the requirements of ASME RTP-1 Appendix M-12. The scope of our ASME certification includes vessels with mechanically bonded or chemically bonded thermoplastic linings (lining classification A).
Thermoplastic welding
Our thermoplastic welders use hot gas hand welding, hot plate butt fusion welding and flow fusion welding to fabricate thermoplastic linings. We specialize in single heat pass flow fusion welding and maximize its use because of the high weld efficiency and consistent weld quality.
Welder qualification
Our welders are qualified per the requirements of ASME RTP-1 Appendix M-12 Article H. Welder qualification includes short term weld strength testing per ASTM C1147. Our welders' certifications are material and process specific.
Forming
RL Industries uses press forming and vacuum forming technologies to fabricate thermoplastic linings. We specialize in the vacuum thermoforming of machine welded flat head and dished head linings. Vacuum thermoforming minimizes the total lining weld length and maximizes the use of machine made welds.
In-house testing
RL Industries is equipped to perform the critical ASTM tests required for FRP dual laminate fabrication: short term weld strength testing per ASTM C1147, climbing drum peel testing per ASTM D1781 and in-plane shear testing per ASTM D3846.
Audited test facility
Our testing facilities are audited and certified under our ASME certification and are supervised by our on-staff professional engineers.
Thermoplastic linings
Dual laminate projects
Case 02009Stamp RTPFEP Lined FRP Chlorine Water Stripper48 in. dia. · 2.3mm FEP/FRP
Case 02062Stamp RTPDual Laminate Vent Scrubbers18 in. dia. · 2.3mm FEP/FRP
Case 03005Stamp RTPDual Laminate High Purity Day Tank36 in. dia. · 2.3mm PFA/FRP
Case 03015Stamp RTPDual Laminate Bromine/Chlorine Scrubber54/72 in. dia. · 2.3mm ETFE/FRP
Case 03086Stamp RTPDual Laminate Scrubber36 in. dia. · 3mm PVDF/FRP
Case 06072Dual Laminate Ultra Pure Water Storage Tanks168 in. dia. · 3mm PVDF/FRP
Case 07006Stamp RTPDual Laminate Acid Storage Tank168 in. dia. · 3mm PVDF/FRP
Case 09020Stamp RTPDual Laminate Vent Scrubbers18 in. dia. · 2.3mm FEP/FRP
Case 98785Dual Laminate Remediation Vessel3mm PP/FRP · 720 in. L
Case 98831Dual Laminate Bromine Extraction Column120 in. dia. · 4mm PVDF/FRP
Case 99023Dual Laminate Bromine Extraction Column156 in. dia. · 4mm PVDF/FRP
Case 99873Dual Laminate Sodium Hydroxide Storage Tank240 in. dia. · 2.3mm ECTFE/FRP
Common questions
Which thermoplastic linings can RL Industries provide?
PFA, FEP, MFA, ETFE, ECTFE, PVDF, PVDF-Flex, polypropylene, CPVC and PVC.
Can a dual laminate vessel carry the ASME RTP-1 mark?
Yes. RL is certified to stamp dual laminate FRP vessels per ASME RTP-1 Appendix M-12, for mechanically bonded or chemically bonded linings (lining classification A). RL is the only company certified to stamp thermoplastic lined FRP dual laminate equipment with the ASME RTP-1 mark.
Which tests are run in-house?
Short term weld strength per ASTM C1147, climbing drum peel per ASTM D1781 and in-plane shear per ASTM D3846.
Get a quote: Dual laminates
Rather talk it through? Call 513.874.2800 or email sales@rl-industries.com.
- The service: what the equipment holds or handles, with temperature and pressure.
- The size: diameter and straight shell, or a drawing or data sheet.
- The code: ASME RTP-1, Section X, or none.